RBRquadrante four-channel radiometer
商品編號:RBRquadrante four-channel radiometer
The RBRquadrante is a multi-spectral radiometer with four channels, capable of measuring multiple wavebands simultaneously, including PAR. It features a high dynamic range, optimized cosine response, and excellent low-light detection, while power consumption and depth rating have been tailored for use in a wide variety of applications.
The RBRquadrante supports measurement of four wavebands within the same sensor package. Tolerant of a wide ranging power supply, data are streamed via RS-232 on the MCBH-6-MP connector. A variety of adaptors make it easy to integrate into existing vehicle payload bays.
The RBRquadrante supports measurement of four wavebands within the same sensor package. Tolerant of a wide ranging power supply, data are streamed via RS-232 on the MCBH-6-MP connector. A variety of adaptors make it easy to integrate into existing vehicle payload bays.
- Low power consumption
- High accuracy
- High dynamic range
- Depths up to 2000m
- RS-232 output
- Compact and lightweight
Physical Connector MCBH-6-MP Diffuser Acrylic Housing Titanium Diameter 63mm Length 57mm, 93mm (with connector) Depth rating 2000m Weight (air) 400g (in air), 210g (in water) Sampling rate Up to 32 Hz |
Power consumption Supply voltage 4.5 to 30V (12V nominal) Sampling 4mJ/sample (4Hz or slower) 3mA/36mW (8Hz or faster) Sleep current 10μA |
Optical radiometry Dynamic range >5.5 decades Absolute calibration1 ±5% Linearity ±1% Operating temperature range -5°C to 35°C Cosine response error (water) ±5% at 0-60° ±10% at 61-82° Azimuth error (water) ±1.5% at 45° Out-of-band rejection2 >25dB (typical), OD 2.5 |
Photosynthetically active radiation Wavelength range 400 to 700nm Full scale range 0-5000µmol/m²/s (minimum) Resolution ±0.010μmol/m²/s |
Narrow-band wavelength channels Centre wavelengths (CWL) 413 / 445 / 475 / 488 / 508 / 532 / 560nm Full width at half-maximum (FWHM) 10nm (for all CWLs except 475nm) 25nm (for CWL 475nm only) Full scale range 0-400μW/cm2/nm (minimum) Resolution3 ±0.001μW/cm2/nm |
1RBR calibrates radiometers with NIST traceable references. 2Out-of-band rejection and resolution are wavelength dependent for narrow-band radiometers. 3Resolution is wavelength dependent for narrow-band radiometers. Note: Dark offset is internally temperature-compensated. |